A bottling line exposes operators to an 8-hour TWA of 96 dBA. An acoustic enclosure around the filler is feasible and would bring the TWA to 92 dBA. The plant manager would rather issue earplugs, which are cheaper and attenuate enough to protect the operators. What does the text of 29 CFR 1910.95(b)(1) require?

Explanation

Section 1910.95(b)(1) requires feasible administrative or engineering controls whenever exposure exceeds Table G-16, and personal protective equipment only where those controls fail to bring levels within the table. Earplugs alone are the tempting choice, but a feasible engineering control cannot be skipped however good the protector's rating. The enclosure still leaves 92 dBA, which Table G-16 allows for only 6 hours, so protectors are needed for the remainder, and waiting for threshold shifts ignores the duty to control exposure now. Source: 29 CFR 1910.95(b)(1) and Table G-16.